LOUDSPEAKER CABLES Technical Data sheet
 

 

 acrobat reader_50x50  

APPLICATIONS

Loudspeaker cables TLYp (L1) and TLgYp (L1) (high flexible) are intended for connection between amplifiers and loudspeakers.

The cables are flat with common PVC insulation (eight shape) on two parallel conductors.

The cables are designed to offer high acoustic parameters confirmed by testing in Electroacoustic Division, Institute of Radioelectronics Warsaw University of Technology.

The cables are suitable for indoor installations connecting fixed and movable equipment.

CONSTRUCTION

- flexible, multiwire conductors, stranded of bare annealed copper wires,

- PVC insulation,

- colours:

            - black with white strip or white with black strip (cross-sections 0.35 and 0.5 mm2),

            - transparent with black or red strip (other cross-sections),

              other colours also available.

AVAILABLE UPON REQUEST

TLYp (L1) OFC and TLgYp (L1) OFC - cables with conductors made of oxygen-free copper (OFC).

TLHp (L1) and TLgHp (L1) - halogen free cables, applied when higher safety in case of fire is required. The cables are flame retardant, their smoke emission in fire is low and released gases are not corrosive.

 

CHARACTERISTICS

TLYp (L1) wires

Conductor cross-section

mm2

0,35

0,5

0,75

1,0

1,5

DC conductor resistance at 20°C

- maximum value

- average value

Ω/km

 

55.4

54.6

 

39.0

37.4

 

26.0

24.8

 

19.5

18.8

 

13.3

12.3

Inductance, approximate

mH/km

422

203

96

51

30

 

TLgYp (L1) wires

Conductor cross-section

mm2

1,5

2,5

4

6

10

DC conductor resistance at 20°C

- maximum value

- average value

Ω/km

 

13.3

12.5

 

7.98

7.5

 

4.95

4.7

 

3.3

3.0

 

1.91

1.8

Inductance, approximate

mH/km

30

9

4

2

1.5

 

Insulation resistance, minimum      200 MΩ×km

Operating voltage                     300 V

Voltage test    1500 V rms

Operating temperature range

      for fixed installation              from -30 to +80 °C
      for movable installation         from -10 to +50 °C

Minimum bending radius            5 x width of wire

Cable combustibility                 flame retardant

Combustibility tests                 PN-EN 60332-1-2; IEC 60332-1-2

 

 The cable meets requirements of the low voltage directive 2014/35/EU

Other construction of conductors and outer dimensions available on request.

TECHNOKABEL S.A. reserves the right to change specifications without prior notice.