COAXIAL CABLES

Technical Data sheet
acrobat reader_50x50
 

APPLICATIONS:

  • CABLES FOR TV ANTENNAS ( Z = 75 Ω ):

YWD 75-0.5/2.9

YWD and XWD 75-0.59/3.7; YWD 75 (T1) 0.59/3.7

RG 59; RG 59 B/U; RG 59 L1/U

YWDek 75-0.59/3.7

YWL and XWL 75-0.63/3.7; YWL 75 (T1) 0.63/3.7

59 F 75-0.8/3.8

YWDek and XWDek 75-0.75/4.8

  • CABLES FOR SATELLITE ANTENNAS AND CABLE TELEVISION

( Z = 75 Ω ):

YWDXpek (T1) 75-1.0/4.8 (optical coverage of braid > 77%)

YWDXpek and XWDXpek 75-1.0/4.8; XzWDXpekw 75-1.0/4.8

11 F 75-1.63/7.25 and 11 F 75 (3) 1.63/7.25

  • CABLES FOR COMPUTER NETWORKS:

Z = 50 Ω:

RG 58; RG 58 (3) C/U

TRIAX 58 A/U

RG 213/U

YWLek 50-2.25/7.25

Z = 93 Ω: RG 62 and RG 71

Z = 125 Ω: RG 63

  • CABLES FOR ELECTRONIC EQUIPMENT:

Z = 50 Ω: YWL 50-0.45/1.3; RG 174; YWLXpek 50 1.35/3.6

Z = 75 Ω: 2YCCY 75 0.4/2.5; YWLXpek and XWLXpek 75-0.45/2.0

  • CABLES FOR RADIO COMMUNICATION ANTENNAS ( Z = 50 Ω ):

RG 58

RG 213/U

YWLXek 50-2.25/7.25

  • CABLES FOR INDUSTRIAL TELEVISION (CCTV) ( Z = 75 Ω ):

RG 59; RG 59 B/U; RG 59 L1/U

YWDXpek and XWDXpek 75-1.0/4.8; XzWDXpekw 75-1.0/4.8

11 F 75-1.63/7.25 and 11 F 75 (3) 1.63/7.25

 

APPLIED ABBREVIATIONS


Cu : bare copper

Fe-Cu : copper-clad steel

Cu-Sn : tined copper

PVC : polyvinyl chloride

 

PE : polyethylene

Al/PETP : aluminium/polyester (2 layers) tape

Al/PETP/Al. : aluminium/polyester/aluminium (3 layers) tape

AL/Cop : copolymer coated aluminium tape

AVAILABLE OPTIONS ( AVAILABLE UPON REQUEST )

Halogen free cables are also available (RG-H; HWD; HWL,…).
Other colours on request.

 

 

 

 

 

 

 

 

 

 

 

Cable name

YWL 50 0,45/1,3

RG 174

RG 58

TRIAX 58 A/U

Product No.

0259 004

0221 023

0221 012

0611 001

         

CONSTRUCTION

Inner conductor:

material

Cu

FeCu

CuSn

CuSn

number and diameter of wires [mm]

7x0,15

7x0,16

19x0,18

7x0,32

diameter [mm]

0,45

0,48

0,9

0,96

Insulation:

material

PE

PE

PE

PE

diameter [mm]

1,3

1,52

3,0

3,0

Outer conductor:

material and CONSTRUCTION

braid Cu

braid Cu (86%)

braid Cu

braid Cu

PE insulation, 4,45 mm

braid CuSn

Sheath:

material

PVC

PVC

PVC

PE

colour

black and white

black and white

black and white

yellow

Diameter Outer [mm]

2,7

2,8

4,95

6,1

         

ELECTRICAL PARAMETERS AT 20°C

Characteristic impedance [Ω]

50 ± 2

50 ± 2

50 ± 2

50 ± 2

Capacitance [pF/m] przy f=1 kHz

97,8

100

103

100

Velocity of propagation [%]

66

66

66

66

DC resistance [mΩ/m]:

inner conductor

152

317

32,5

31

outer conductor

45,3

43

13,4

15,5/14,1

Attenuation [dB/100 m] – average, at frequency [MHz]:

 

50

21,3

19,0

10,5

10,8

100

30,4

30,0

15,4

16,1

200

43,1

45,0

22,6

 

800

90,0

84,0

50,1

 

1000

101,7

92,0

58,3

78,7

Return loss [dB] - min.

20

20

20

20

Shielding attenuation [dB] - min.

40

40

40

40

         

OTHERS DATA

Reference standards

MIL-C-17

MIL-C-17/119 G

MIL-C-17/28

DT 22/06/03

Operating temperature range [°C]

-20 ¸ +70

-40 ¸ +70

-40 ¸ +70

-40 ¸ +70

Minimum bending radius [mm]

15

15

25

50

Weight [kg/km]

11,5

12,0

40,0

61,0

 

 

Cable name

YWLXpek 50 1,35/3,6

YWLek 50 2,25/7,25

RG 213/U

Product No.

0264 001

0261 002

0221 018

       

CONSTRUCTION

Inner conductor:

material

Cu

Cu

Cu

number and diameter of wires [mm]

7x0,45

7x0,75

7x0,75

diameter [mm]

1,35

2,25

2,25

Insulation:

material

PE - piankowy

PE

PE

diameter [mm]

3,6

7,3

7,3

Outer conductor:

material and CONSTRUCTION

taśma Al/PETP

braid CuSn

taśma Al/PETP/Al

braid CuSn

braid Cu

Sheath:

material

PVC

PVC

PVC

colour

black and white

black and white

black

Diameter Outer [mm]

5,3

10,1

10,2

       

ELECTRICAL PARAMETERS AT 20°C

Characteristic impedance [Ω]

50 ± 2

50 ± 2

50 ± 2

Capacitance [pF/m] przy f=1 kHz

87

100

100

Velocity of propagation [%]

78

66

66

DC resistance [mΩ/m]:

inner conductor

17,0

5,7

5,7

outer conductor

15,0

12,7

5,8

Attenuation [dB/100 m] – average, at frequency [MHz]:

 

50

7,4

3,9

4,5

100

10,0

5,4

6,5

200

14,0

7,9

9,4

800

29,0

18,4

21,7

1000

33,0

21,1

21,1

2400

54,0

38,5

46,1

Return loss [dB] - min.

20

20

20

Shielding attenuation [dB] - min.

40

60

40

       

OTHERS DATA

Reference standards

DT 68/04/05

IEC 60096-2A,PN-EN 50117

MIL-C-17/74 C

Operating temperature range [°C]

-20 ¸ +70

-20 ¸ +70

-20 ¸ +70

Minimum bending radius [mm]

50

70

70

Weight [kg/km]

38,5

130

154

 

 

 

Cable name

2YCCY 75 0,4/2,5

YWD 75 0,5/2,9

YWD 75 0,59/3,7

XWD 75 0,59/3,7

 

Product No.

0255 003

0253 002

0253 003

0254 003

 
           

CONSTRUCTION

 

Inner conductor:

 

material

Fe-Cu

Cu

Cu

Cu

 

number and diameter of wires [mm]

1x0,0,4

1x0,5

1x0,59

1x0,59

 

diameter [mm]

0,4

0,5

0,59

0,59

 

Insulation:

 

material

PE

PE

PE

PE

 

diameter [mm]

2,5

2,9

3,7

3,7

 

Outer conductor:

 

material and CONSTRUCTION

braid CuSn

tape separator

braid CuSn

braid Cu

braid Cu

braid Cu

 

Sheath:

 

material

PVC

PVC

PVC

PE

 

colour

olive with yellow stripe

white

black and white

black

 

Diameter Outer [mm]

4,5

5

5,5

5,5

 
           

ELECTRICAL PARAMETERS AT 20°C

 

Characteristic impedance [Ω]

75 ± 3

75 ± 5

75 ± 3

75 ± 3

 

Capacitance [pF/m] przy f=1 kHz

70

69,6

67

67

 
 

Velocity of propagation [%]

66

66

66

66

 

DC resistance [mΩ/m]:

 

inner conductor

360

86,2

63

63

 

outer conductor

24/24

57,6

27,2

27,2

 

Attenuation [dB/100 m] – average, at frequency [MHz]:

   

50

11,5

9,7

8,4

8,4

 

100

16

15

13,8

13,8

 

200

23

22,9

18,5

18,5

 

800

 

50,2

36

36

 

1000

 

54

40,9

40,9

 

2400

   

68,5

68,5

 

Return loss [dB] - min.

26

20

20

20

 

Shielding attenuation [dB] - min.

50

40

40

40

 
           

OTHERS DATA

 

Reference standards

DT 6/07/01

IEC 60096-2A

IEC 60096-2A

IEC 60096-2A

 

PN-EN 50117

PN-EN 50117

PN-EN 50117

 

Operating temperature range [°C]

-20 ¸ +70

-20 ¸ +70

-20 ¸ +70

-40 ¸ +70

 

Minimum bending radius [mm]

25

30

30

35

 

Weight [kg/km]

31

29

34

43

 

 

 

Cable name

YWD 75 (T1) 0,59/3,7

RG 59

RG 59 L1/U

RG 59 B/U

Product No.

0253 010

0221 002

0221 022

0221 008

         

CONSTRUCTION

Inner conductor:

material

Cu

Fe-Cu

Fe-Cu

Cu

number and diameter of wires [mm]

1x0,59

1x0,59

1x0,59

1x0,59

diameter [mm]

0,59

0,59

0,59

0,59

Insulation:

material

PE

PE

PE

PE

diameter [mm]

3,7

3,7

3,7

3,7

Outer conductor:

material and CONSTRUCTION

braid Cu

braid Cu

braid Cu

braid Cu

Sheath:

material

PVC

PVC

PVC

PE

colour

black and white

black

black

black and white

Diameter Outer [mm]

5,9

6,15

6,15

6,15

         

ELECTRICAL PARAMETERS AT 20°C

Characteristic impedance [Ω]

75 ± 3

75 ± 3

75 ± 3

75 ± 3

Capacitance [pF/m] przy f=1 kHz

67,0

67,0

67,0

67,0

Velocity of propagation [%]

66

66

66

66

DC resistance [mΩ/m]:

inner conductor

63,0

157,5

157,5

63,0

outer conductor

16,3

8,0

16,3

8,0

Attenuation [dB/100 m] – average, at frequency [MHz]:

 

50

7,4

7,7

9,0

7,7

100

10,7

11,3

13,7

11,1

200

15,5

16,5

18,2

16,2

800

33,7

35,6

36,3

35,6

1000

38,1

40,5

41,5

40,5

2400

55,4

59,5

65,0

59,5

Return loss [dB] - min.

20

20

20

20

Shielding attenuation [dB] - min.

40

40

40

40

         

OTHERS DATA

Reference standards

IEC 60096-2A
PN-EN 50117

MIL-C-17/29C

MIL-C-17

MIL-C-17/29C

Operating temperature range [°C]

-20 ¸ +70

-40 ¸ +70

-40 ¸ +70

-40 ¸ +70

Minimum bending radius [mm]

35

35

35

35

Weight [kg/km]

43

56

45

56

 

 


Cable name

YWDek 75 0,59/3,7

YWL 75 0,63/3,7

YWL 75 (T1) 0,63/3,7

XWL 75 0,63/3,7

Product No.

0254 002

0259 001

0259 010

0259 006

         

CONSTRUCTION

Inner conductor:

material

Cu

Cu

Cu

Cu

number and diameter of wires [mm]

1x0,59

7x0,2

7x0,2

7x0,2

diameter [mm]

0,59

0,6

0,6

0,6

Insulation:

material

PE

PE

PE

PE

diameter [mm]

3,7

3,7

3,7

3,7

Outer conductor:

material and CONSTRUCTION

Al/PETP tape
braid CuSn

braid Cu

braid Cu

braid Cu

Sheath:

material

PVC

PVC

PVC

PE

colour

black and white

black and white

black and white

black and white

Diameter Outer [mm]

5,8

5,5

5,9

5,5

         

ELECTRICAL PARAMETERS AT 20°C

Characteristic impedance [Ω]

75 ± 3

75 ± 3

75 ± 3

75 ± 3

Capacitance [pF/m] przy f=1 kHz

67,4

64,7

64,7

64,7

Velocity of propagation [%]

66

66

66

66

DC resistance [mΩ/m]:

inner conductor

63,0

84,2

84,2

84,2

outer conductor

33,6

27,2

16,3

16,3

Attenuation [dB/100 m] – average, at frequency [MHz]:

 

50

7,2

8,4

7,9

8,4

100

10,1

11,7

11,2

11,7

200

14,7

16,8

16,3

16,8

800

33,0

36,0

34,7

36,0

1000

38,1

40,9

39,1

40,9

2400

57,2

68,5

64,4

68,5

Return loss [dB] - min.

20

20

20

20

Shielding attenuation [dB] - min.

75

40

40

40

         

OTHERS DATA

Reference standards

IEC 60096-2A
PN-EN 50117

IEC 60096-2A
PN-EN 50117

IEC 60096-2A
PN-EN 50117

IEC 60096-2A
PN-EN 50117

Operating temperature range [°C]

-20 ¸ +70

-20 ¸ +70

-20 ¸ +70

-40 ¸ +70

Minimum bending radius [mm]

35

30

30

35

Weight [kg/km]

35

33

43

30

 

 

Cable name

YWDek 75 0,75/4,8

XWDek 75 0,75/4,8

YWLXpek 75 0,45/2,0

59 F 75 0,8/3,8

Product No.

0254 008

0254 007

0263 002

0001 001

         

CONSTRUCTION

Inner conductor:

material

Cu

Cu

Cu

Cu

number and diameter of wires [mm]

1x0,75

1x0,75

7x0,15

1x0,8

diameter [mm]

0,75

0,75

0,45

0,8

Insulation:

material

PE

PE

foam-skin PE

foam-skin PE

diameter [mm]

4,8

4,8

2,0

3,8

Outer conductor:

material and CONSTRUCTION

Al/PETP/Al tape
braid CuSn

Al/PETP/Al tape
braid CuSn

Al/PETP/Al tape
braid CuSn

Al/PETP/Al tape
braid CuSn

Sheath:

material

PVC

PE

PVC

PE

colour

black and white

black

black and white

black and white

Diameter Outer [mm]

7,3

7,3

3,6

6,0

         

ELECTRICAL PARAMETERS AT 20°C

Characteristic impedance [Ω]

75 ± 3

75 ± 3

75 ± 3

75 ± 3

Capacitance [pF/m] przy f=1 kHz

67,1

67,1

60,6

55,7

Velocity of propagation [%]

66

66

78

78

DC resistance [mΩ/m]:

inner conductor

38,7

38,7

176,0

35,6

outer conductor

13,0

13,0

16,6

23,3

Attenuation [dB/100 m] – average, at frequency [MHz]:

 

50

5,8

5,8

11,8

6,0

100

8,4

8,4

16,9

8,3

200

11,7

11,7

24,4

11,8

800

26,5

26,5

49,6

25,8

1000

30,3

30,3

55,7

29,2

2400

50,9

50,9

 

46,2

Return loss [dB] - min.

20

20

20

20

Shielding attenuation [dB] - min.

75

40

40

40

         

OTHERS DATA

Reference standards

IEC 60096-2A
PN-EN 50117

IEC 60096-2A
PN-EN 50117

IEC 60096-2A
PN-EN 50117

IEC 60096-2A
PN-EN 50117

Operating temperature range [°C]

-20 ¸ +70

-40 ¸ +70

-20 ¸ +70

-20 ¸ +70

Minimum bending radius [mm]

45

48

18

40

Weight [kg/km]

64,5

64,5

17,5

37

 

 

Cable name

YWDXpek (T1) 75 1,0/4,8

YWDXpek 75 1,0/4,8

XWDXpek 75 1,0/4,8

RG 6 L1/U

Product No.

0258 013

0258 010

0258 005

0221 021

         

CONSTRUCTION

Inner conductor:

material

Cu

Cu

Cu

Cu

number and diameter of wires [mm]

1x1,0

1x1,0

1x1,0

1x1,0

diameter [mm]

1,0

1,0

1,0

1,0

Insulation:

material

foam-skin PE

foam-skin PE

foam-skin PE

foam-skin PE

diameter [mm]

4,8

4,8

4,8

4,8

Outer conductor:

material and CONSTRUCTION

Al/PETP/Al tape
braid CuSn
density > 77%

Al/PETP/Al tape
braid CuSn

Al/PETP/Al tape
braid CuSn

Al/PETP/Al tape
braid CuSn

Sheath:

material

PVC

PVC

PE

PVC

colour

black and white

black and white

black

black and white

Diameter Outer [mm]

7,3

7,3

3,6

6,0

         

ELECTRICAL PARAMETERS AT 20°C

Characteristic impedance [Ω]

75 ± 3

75 ± 3

75 ± 3

75 ± 3

Capacitance [pF/m] przy f=1 kHz

57,0

57,0

57,0

57,0

Velocity of propagation [%]

78

78

78

78

DC resistance [mΩ/m]:

inner conductor

22,0

22,0

22,0

22,0

outer conductor

8,0

20,0

20,0

21,0

Attenuation [dB/100 m] – average, at frequency [MHz]:

 

50

4,6

6,0

6,0

6,0

100

6,4

8,3

8,3

8,3

200

9,1

11,8

11,8

11,8

800

20,2

25,8

25,8

25,8

1000

22,0

29,2

29,2

29,2

2400

38,5

46,2

46,2

46,2

Return loss [dB] - min.

20

20

20

20

Shielding attenuation [dB] - min.

75

75

75

75

         

OTHERS DATA

Reference standards

IEC 60096-2A
PN-EN 50117

IEC 60096-2A
PN-EN 50117

IEC 60096-2A
PN-EN 50117

IEC 60096-2A
PN-EN 50117

Operating temperature range [°C]

-20 ¸ +70

-20 ¸ +70

-40 ¸ +70

-20 ¸ +70

Minimum bending radius [mm]

45

45

60

45

Weight [kg/km]

57

43

37

45

 

 

Cable name

11F 75 1,63/7,25

RG 62

RG 71

RG 63

Product No.

0001 002

0221 003

0221 005

0221 001

         

CONSTRUCTION

Inner conductor:

material

Cu

Fe-Cu

Fe-Cu

Fe-Cu

number and diameter of wires [mm]

1x1,63

1x0,64

1x0,64

1x0,64

diameter [mm]

1,0

0,64

0,64

0,64

Insulation:

material

foam-skin PE

PE- air

PE- air

PE- air

diameter [mm]

7,25

3,7

3,7

7,2

Outer conductor:

material and CONSTRUCTION

Al/PETP/Al
 tape braid CuSn

braid Cu

braid Cu
braid CuSn


braid Cu

Sheath:

material

PVC

PVC

PE

PVC

colour

black and white

black

black

black and white

Diameter Outer [mm]

10,0

6,15

6,2

10,4

         

ELECTRICAL PARAMETERS AT 20°C

Characteristic impedance [Ω]

75 ± 3

93 ± 5

93 ± 5

125 ± 6

Capacitance [pF/m] przy f=1 kHz

57,0

44,5

43,4

33,1

Velocity of propagation [%]

78

83

83

84

DC resistance [mΩ/m]:

inner conductor

8,0

138,8

138,8

138,8

outer conductor

14,5

8,0

4,5

3,3

Attenuation [dB/100 m] – average, at frequency [MHz]:

 

50

3,1

6,3

6,5

4,3

100

4,4

9,2

9,3

6,2

200

6,4

12,6

13,3

8,8

800

14,0

26,1

28,1

18,1

1000

16,0

30,8

31,8

20,4

2400

29,4

     

Return loss [dB] - min.

20

20

20

20

Shielding attenuation [dB] - min.

75

40

50

40

         

OTHERS DATA

Reference standards

IEC 60096-2A
PN-EN 50117

MIL-C-17/30D

MIL-C-17/90A

MIL-C-17/30D

Operating temperature range [°C]

-20 ¸ +70

-20 ¸ +70

-40 ¸ +70

-40 ¸ +70

Minimum bending radius [mm]

60

35

35

110

Weight [kg/km]

93

56

57

125

 

 

Cable name

RG 58 (3) C/U

XzWDXpekw 75 1,0/4,8

11F (3) 75 1,63/7,25

Product No.

0221 013

0276 002

0001 004

       

CONSTRUCTION

Inner conductor:

material

CuSn

Cu

Cu

number and diameter of wires [mm]

19x0,18

1x1,0

1x1,63

diameter [mm]

0,9

1,0

1,63

Insulation:

material

PE

foam-skin PE

foam-skin PE

diameter [mm]

2,95

4,8

7,25

Outer conductor:

material and CONSTRUCTION

braid CuSn
Al/Cop tape

Al/PETP/Al tape
braid CuSn
Al/Cop tape

Al/PETP/Al tape
braid CuSn
Al/Cop tape

Sheath:

material

gel
PE

gel
PE

gel
PE

colour

black

black

black

Diameter Outer [mm]

6,8

8,4

11,5

       

ELECTRICAL PARAMETERS AT 20°C

Characteristic impedance [Ω]

50 ± 2

75 ± 3

75 ± 3

Capacitance [pF/m] przy f=1 kHz

103,0

60,0

60,0

Velocity of propagation [%]

66

78

78

DC resistance [mΩ/m]:

inner conductor

32,5

22,0

8,0

outer conductor

13,4

9,2

8,5

Attenuation [dB/100 m] – average, at frequency [MHz]:

 

50

11,4

4,6

3,1

100

16,6

6,4

4,4

200

24,4

9,1

6,4

800

73,0

20,2

14,4

1000

87,0

22,0

16,7

2400

 

38,5

31,0

Return loss [dB] - min.

20

20

20

Shielding attenuation [dB] - min.

75

75

75

       

OTHERS DATA

Reference standards

MIL-C-17

IEC 60096-2A
PN-EN 50117

IEC 60096-2A
PN-EN 50117

Operating temperature range [°C]

-40 ¸ +70

-40 ¸ +70

-40 ¸ +70

Minimum bending radius [mm]

70

90

120

Weight [kg/km]

58

74

111,0

 

SPECIAL CABLES PS-Y-29
Technical Data sheet

acrobat reader_50x50
 
APPLICATIONS

Hybrid cables PS-Y-29 intended for operation in CCTV networks.

Cables are equipped with coax WD 75-0,59/3,7 for visual signal transmission and a group of insulated conductors for camera power supply and control signals transmission.

The cables are suitable for fixed indoor and outdoor installations.

CONSTRUCTION

coaxial cable WD 75-0,59/3,7

- soft solid copper conductor, diameter 0.59 mm,

- polyethylene (PE) insulation, diameter 3.7 mm,

- copper wire braid,

LiY wires

- flexible, multiwire conductors, stranded of bare annealed copper wires (tin-plated on request), meeting requirements of class 5 per PN-EN 60228,

- PVC insulation - identification colour code in accordance with DIN VDE 47100,

- insulated conductors twisted into pair,

- pair wrapped in polyester tape,

PS-Y-29 cable

- white (RAL 9010) PVC cable sheath, (8 shape) extruded on the parallel arranged coaxial and pair of insulated conductors, other colours also available.
 
CHARACTERISTICS

Coaxial cable WD 75-0,59/3,7

Characteristic impedance 75 ± 3 Ω

Capacitance at 1 kHz, approximate 67 nF/km

Velocity of propagation 66 %

DC resistance at 20°C, approximate

inner conductor 63 Ω/km

outer conductor 27.2 Ω/km

LiY wires

Operating voltage Uo/U 300/300 V

Operating voltage, peak value 500 V

Voltage test 1500 V rms

DC conductor resistance at 20°C, maximum:

conductor 0.50 mm2 39.0 Ω/km

conductor 0.75 mm2 26.0 Ω/km

conductor 1.0 mm2 19.5 Ω/km

Insulation resistance, minimum 20 MΩ∙km

Inductance, approximate 0.7 mH/km

Cable PS-Y-29

Operating temperature range

during operation from - 30 to + 70°C
during installation from - 10 to + 50°C

Minimum bending radius 10 x cable diameter

Cable combustibility flame retardant

Combustibility tests PN-EN 60332-1-2, IEC 60332-1-2

Reference standards

coaxial cable PN-91/T-90601, IEC 61156-1

LiY wires DIN VDE 0812

The cable meets requirements of the low voltage directive 2014/35/EU

Attenuation loss [dB/100m] average - at frequency [MHz]:

1

1.0

50

7.4

100

10.5

200

15.1

300

18.8

500

24.8

800

32.0

1000

36.3

1500

45.6

2000

55.7

2400

56.9