COAXIAL CABLES |
Technical Data sheet |
APPLICATIONS:
- CABLES FOR TV ANTENNAS ( Z = 75 Ω ):
YWD 75-0.5/2.9
YWD and XWD 75-0.59/3.7; YWD 75 (T1) 0.59/3.7
RG 59; RG 59 B/U; RG 59 L1/U
YWDek 75-0.59/3.7
YWL and XWL 75-0.63/3.7; YWL 75 (T1) 0.63/3.7
59 F 75-0.8/3.8
YWDek and XWDek 75-0.75/4.8
- CABLES FOR SATELLITE ANTENNAS AND CABLE TELEVISION
( Z = 75 Ω ):
YWDXpek (T1) 75-1.0/4.8 (optical coverage of braid > 77%)
YWDXpek and XWDXpek 75-1.0/4.8; XzWDXpekw 75-1.0/4.8
11 F 75-1.63/7.25 and 11 F 75 (3) 1.63/7.25
- CABLES FOR COMPUTER NETWORKS:
Z = 50 Ω:
RG 58; RG 58 (3) C/U
TRIAX 58 A/U
RG 213/U
YWLek 50-2.25/7.25
Z = 93 Ω: RG 62 and RG 71
Z = 125 Ω: RG 63
- CABLES FOR ELECTRONIC EQUIPMENT:
Z = 50 Ω: YWL 50-0.45/1.3; RG 174; YWLXpek 50 1.35/3.6
Z = 75 Ω: 2YCCY 75 0.4/2.5; YWLXpek and XWLXpek 75-0.45/2.0
- CABLES FOR RADIO COMMUNICATION ANTENNAS ( Z = 50 Ω ):
RG 58
RG 213/U
YWLXek 50-2.25/7.25
- CABLES FOR INDUSTRIAL TELEVISION (CCTV) ( Z = 75 Ω ):
RG 59; RG 59 B/U; RG 59 L1/U
YWDXpek and XWDXpek 75-1.0/4.8; XzWDXpekw 75-1.0/4.8
11 F 75-1.63/7.25 and 11 F 75 (3) 1.63/7.25
APPLIED ABBREVIATIONS
Fe-Cu : copper-clad steel Cu-Sn : tined copper PVC : polyvinyl chloride |
PE : polyethylene Al/PETP : aluminium/polyester (2 layers) tape Al/PETP/Al. : aluminium/polyester/aluminium (3 layers) tape AL/Cop : copolymer coated aluminium tape |
AVAILABLE OPTIONS ( AVAILABLE UPON REQUEST ) Halogen free cables are also available (RG-H; HWD; HWL,…). |
|
|
|
|
|
Cable name |
YWL 50 0,45/1,3 |
RG 174 |
RG 58 |
TRIAX 58 A/U |
Product No. |
0259 004 |
0221 023 |
0221 012 |
0611 001 |
CONSTRUCTION |
||||
Inner conductor: |
||||
material |
Cu |
FeCu |
CuSn |
CuSn |
number and diameter of wires [mm] |
7x0,15 |
7x0,16 |
19x0,18 |
7x0,32 |
diameter [mm] |
0,45 |
0,48 |
0,9 |
0,96 |
Insulation: |
||||
material |
PE |
PE |
PE |
PE |
diameter [mm] |
1,3 |
1,52 |
3,0 |
3,0 |
Outer conductor: |
||||
material and CONSTRUCTION |
braid Cu |
braid Cu (86%) |
braid Cu |
braid Cu PE insulation, 4,45 mm braid CuSn |
Sheath: |
||||
material |
PVC |
PVC |
PVC |
PE |
colour |
black and white |
black and white |
black and white |
yellow |
Diameter Outer [mm] |
2,7 |
2,8 |
4,95 |
6,1 |
ELECTRICAL PARAMETERS AT 20°C |
||||
Characteristic impedance [Ω] |
50 ± 2 |
50 ± 2 |
50 ± 2 |
50 ± 2 |
Capacitance [pF/m] przy f=1 kHz |
97,8 |
100 |
103 |
100 |
Velocity of propagation [%] |
66 |
66 |
66 |
66 |
DC resistance [mΩ/m]: |
||||
inner conductor |
152 |
317 |
32,5 |
31 |
outer conductor |
45,3 |
43 |
13,4 |
15,5/14,1 |
Attenuation [dB/100 m] – average, at frequency [MHz]: |
||||
50 |
21,3 |
19,0 |
10,5 |
10,8 |
100 |
30,4 |
30,0 |
15,4 |
16,1 |
200 |
43,1 |
45,0 |
22,6 |
|
800 |
90,0 |
84,0 |
50,1 |
|
1000 |
101,7 |
92,0 |
58,3 |
78,7 |
Return loss [dB] - min. |
20 |
20 |
20 |
20 |
Shielding attenuation [dB] - min. |
40 |
40 |
40 |
40 |
OTHERS DATA |
||||
Reference standards |
MIL-C-17 |
MIL-C-17/119 G |
MIL-C-17/28 |
DT 22/06/03 |
Operating temperature range [°C] |
-20 ¸ +70 |
-40 ¸ +70 |
-40 ¸ +70 |
-40 ¸ +70 |
Minimum bending radius [mm] |
15 |
15 |
25 |
50 |
Weight [kg/km] |
11,5 |
12,0 |
40,0 |
61,0 |
|
|
|
|
Cable name |
YWLXpek 50 1,35/3,6 |
YWLek 50 2,25/7,25 |
RG 213/U |
Product No. |
0264 001 |
0261 002 |
0221 018 |
CONSTRUCTION |
|||
Inner conductor: |
|||
material |
Cu |
Cu |
Cu |
number and diameter of wires [mm] |
7x0,45 |
7x0,75 |
7x0,75 |
diameter [mm] |
1,35 |
2,25 |
2,25 |
Insulation: |
|||
material |
PE - piankowy |
PE |
PE |
diameter [mm] |
3,6 |
7,3 |
7,3 |
Outer conductor: |
|||
material and CONSTRUCTION |
taśma Al/PETP braid CuSn |
taśma Al/PETP/Al braid CuSn |
braid Cu |
Sheath: |
|||
material |
PVC |
PVC |
PVC |
colour |
black and white |
black and white |
black |
Diameter Outer [mm] |
5,3 |
10,1 |
10,2 |
ELECTRICAL PARAMETERS AT 20°C |
|||
Characteristic impedance [Ω] |
50 ± 2 |
50 ± 2 |
50 ± 2 |
Capacitance [pF/m] przy f=1 kHz |
87 |
100 |
100 |
Velocity of propagation [%] |
78 |
66 |
66 |
DC resistance [mΩ/m]: |
|||
inner conductor |
17,0 |
5,7 |
5,7 |
outer conductor |
15,0 |
12,7 |
5,8 |
Attenuation [dB/100 m] – average, at frequency [MHz]: |
|||
50 |
7,4 |
3,9 |
4,5 |
100 |
10,0 |
5,4 |
6,5 |
200 |
14,0 |
7,9 |
9,4 |
800 |
29,0 |
18,4 |
21,7 |
1000 |
33,0 |
21,1 |
21,1 |
2400 |
54,0 |
38,5 |
46,1 |
Return loss [dB] - min. |
20 |
20 |
20 |
Shielding attenuation [dB] - min. |
40 |
60 |
40 |
OTHERS DATA |
|||
Reference standards |
DT 68/04/05 |
IEC 60096-2A,PN-EN 50117 |
MIL-C-17/74 C |
Operating temperature range [°C] |
-20 ¸ +70 |
-20 ¸ +70 |
-20 ¸ +70 |
Minimum bending radius [mm] |
50 |
70 |
70 |
Weight [kg/km] |
38,5 |
130 |
154 |
|
|
|
|
||
Cable name |
2YCCY 75 0,4/2,5 |
YWD 75 0,5/2,9 |
YWD 75 0,59/3,7 |
XWD 75 0,59/3,7 |
|
Product No. |
0255 003 |
0253 002 |
0253 003 |
0254 003 |
|
CONSTRUCTION |
|||||
Inner conductor: |
|||||
material |
Fe-Cu |
Cu |
Cu |
Cu |
|
number and diameter of wires [mm] |
1x0,0,4 |
1x0,5 |
1x0,59 |
1x0,59 |
|
diameter [mm] |
0,4 |
0,5 |
0,59 |
0,59 |
|
Insulation: |
|||||
material |
PE |
PE |
PE |
PE |
|
diameter [mm] |
2,5 |
2,9 |
3,7 |
3,7 |
|
Outer conductor: |
|||||
material and CONSTRUCTION |
braid CuSn tape separator braid CuSn |
braid Cu |
braid Cu |
braid Cu |
|
Sheath: |
|||||
material |
PVC |
PVC |
PVC |
PE |
|
colour |
olive with yellow stripe |
white |
black and white |
black |
|
Diameter Outer [mm] |
4,5 |
5 |
5,5 |
5,5 |
|
ELECTRICAL PARAMETERS AT 20°C |
|||||
Characteristic impedance [Ω] |
75 ± 3 |
75 ± 5 |
75 ± 3 |
75 ± 3 |
|
Capacitance [pF/m] przy f=1 kHz |
70 |
69,6 |
67 |
67 |
|
Velocity of propagation [%] |
66 |
66 |
66 |
66 |
|
DC resistance [mΩ/m]: |
|||||
inner conductor |
360 |
86,2 |
63 |
63 |
|
outer conductor |
24/24 |
57,6 |
27,2 |
27,2 |
|
Attenuation [dB/100 m] – average, at frequency [MHz]: |
|||||
50 |
11,5 |
9,7 |
8,4 |
8,4 |
|
100 |
16 |
15 |
13,8 |
13,8 |
|
200 |
23 |
22,9 |
18,5 |
18,5 |
|
800 |
50,2 |
36 |
36 |
||
1000 |
54 |
40,9 |
40,9 |
||
2400 |
68,5 |
68,5 |
|||
Return loss [dB] - min. |
26 |
20 |
20 |
20 |
|
Shielding attenuation [dB] - min. |
50 |
40 |
40 |
40 |
|
OTHERS DATA |
|||||
Reference standards |
DT 6/07/01 |
IEC 60096-2A |
IEC 60096-2A |
IEC 60096-2A |
|
PN-EN 50117 |
PN-EN 50117 |
PN-EN 50117 |
|||
Operating temperature range [°C] |
-20 ¸ +70 |
-20 ¸ +70 |
-20 ¸ +70 |
-40 ¸ +70 |
|
Minimum bending radius [mm] |
25 |
30 |
30 |
35 |
|
Weight [kg/km] |
31 |
29 |
34 |
43 |
|
|
|
|
|
Cable name |
YWD 75 (T1) 0,59/3,7 |
RG 59 |
RG 59 L1/U |
RG 59 B/U |
Product No. |
0253 010 |
0221 002 |
0221 022 |
0221 008 |
CONSTRUCTION |
||||
Inner conductor: |
||||
material |
Cu |
Fe-Cu |
Fe-Cu |
Cu |
number and diameter of wires [mm] |
1x0,59 |
1x0,59 |
1x0,59 |
1x0,59 |
diameter [mm] |
0,59 |
0,59 |
0,59 |
0,59 |
Insulation: |
||||
material |
PE |
PE |
PE |
PE |
diameter [mm] |
3,7 |
3,7 |
3,7 |
3,7 |
Outer conductor: |
||||
material and CONSTRUCTION |
braid Cu |
braid Cu |
braid Cu |
braid Cu |
Sheath: |
||||
material |
PVC |
PVC |
PVC |
PE |
colour |
black and white |
black |
black |
black and white |
Diameter Outer [mm] |
5,9 |
6,15 |
6,15 |
6,15 |
ELECTRICAL PARAMETERS AT 20°C |
||||
Characteristic impedance [Ω] |
75 ± 3 |
75 ± 3 |
75 ± 3 |
75 ± 3 |
Capacitance [pF/m] przy f=1 kHz |
67,0 |
67,0 |
67,0 |
67,0 |
Velocity of propagation [%] |
66 |
66 |
66 |
66 |
DC resistance [mΩ/m]: |
||||
inner conductor |
63,0 |
157,5 |
157,5 |
63,0 |
outer conductor |
16,3 |
8,0 |
16,3 |
8,0 |
Attenuation [dB/100 m] – average, at frequency [MHz]: |
||||
50 |
7,4 |
7,7 |
9,0 |
7,7 |
100 |
10,7 |
11,3 |
13,7 |
11,1 |
200 |
15,5 |
16,5 |
18,2 |
16,2 |
800 |
33,7 |
35,6 |
36,3 |
35,6 |
1000 |
38,1 |
40,5 |
41,5 |
40,5 |
2400 |
55,4 |
59,5 |
65,0 |
59,5 |
Return loss [dB] - min. |
20 |
20 |
20 |
20 |
Shielding attenuation [dB] - min. |
40 |
40 |
40 |
40 |
OTHERS DATA |
||||
Reference standards |
IEC 60096-2A |
MIL-C-17/29C |
MIL-C-17 |
MIL-C-17/29C |
Operating temperature range [°C] |
-20 ¸ +70 |
-40 ¸ +70 |
-40 ¸ +70 |
-40 ¸ +70 |
Minimum bending radius [mm] |
35 |
35 |
35 |
35 |
Weight [kg/km] |
43 |
56 |
45 |
56 |
|
|
|
|
|
Cable name |
YWDek 75 0,59/3,7 |
YWL 75 0,63/3,7 |
YWL 75 (T1) 0,63/3,7 |
XWL 75 0,63/3,7 |
Product No. |
0254 002 |
0259 001 |
0259 010 |
0259 006 |
CONSTRUCTION |
||||
Inner conductor: |
||||
material |
Cu |
Cu |
Cu |
Cu |
number and diameter of wires [mm] |
1x0,59 |
7x0,2 |
7x0,2 |
7x0,2 |
diameter [mm] |
0,59 |
0,6 |
0,6 |
0,6 |
Insulation: |
||||
material |
PE |
PE |
PE |
PE |
diameter [mm] |
3,7 |
3,7 |
3,7 |
3,7 |
Outer conductor: |
||||
material and CONSTRUCTION |
Al/PETP tape |
braid Cu |
braid Cu |
braid Cu |
Sheath: |
||||
material |
PVC |
PVC |
PVC |
PE |
colour |
black and white |
black and white |
black and white |
black and white |
Diameter Outer [mm] |
5,8 |
5,5 |
5,9 |
5,5 |
ELECTRICAL PARAMETERS AT 20°C |
||||
Characteristic impedance [Ω] |
75 ± 3 |
75 ± 3 |
75 ± 3 |
75 ± 3 |
Capacitance [pF/m] przy f=1 kHz |
67,4 |
64,7 |
64,7 |
64,7 |
Velocity of propagation [%] |
66 |
66 |
66 |
66 |
DC resistance [mΩ/m]: |
||||
inner conductor |
63,0 |
84,2 |
84,2 |
84,2 |
outer conductor |
33,6 |
27,2 |
16,3 |
16,3 |
Attenuation [dB/100 m] – average, at frequency [MHz]: |
||||
50 |
7,2 |
8,4 |
7,9 |
8,4 |
100 |
10,1 |
11,7 |
11,2 |
11,7 |
200 |
14,7 |
16,8 |
16,3 |
16,8 |
800 |
33,0 |
36,0 |
34,7 |
36,0 |
1000 |
38,1 |
40,9 |
39,1 |
40,9 |
2400 |
57,2 |
68,5 |
64,4 |
68,5 |
Return loss [dB] - min. |
20 |
20 |
20 |
20 |
Shielding attenuation [dB] - min. |
75 |
40 |
40 |
40 |
OTHERS DATA |
||||
Reference standards |
IEC 60096-2A |
IEC 60096-2A |
IEC 60096-2A |
IEC 60096-2A |
Operating temperature range [°C] |
-20 ¸ +70 |
-20 ¸ +70 |
-20 ¸ +70 |
-40 ¸ +70 |
Minimum bending radius [mm] |
35 |
30 |
30 |
35 |
Weight [kg/km] |
35 |
33 |
43 |
30 |
|
|
|
|
|
Cable name |
YWDek 75 0,75/4,8 |
XWDek 75 0,75/4,8 |
YWLXpek 75 0,45/2,0 |
59 F 75 0,8/3,8 |
Product No. |
0254 008 |
0254 007 |
0263 002 |
0001 001 |
CONSTRUCTION |
||||
Inner conductor: |
||||
material |
Cu |
Cu |
Cu |
Cu |
number and diameter of wires [mm] |
1x0,75 |
1x0,75 |
7x0,15 |
1x0,8 |
diameter [mm] |
0,75 |
0,75 |
0,45 |
0,8 |
Insulation: |
||||
material |
PE |
PE |
foam-skin PE |
foam-skin PE |
diameter [mm] |
4,8 |
4,8 |
2,0 |
3,8 |
Outer conductor: |
||||
material and CONSTRUCTION |
Al/PETP/Al tape |
Al/PETP/Al tape |
Al/PETP/Al tape |
Al/PETP/Al tape |
Sheath: |
||||
material |
PVC |
PE |
PVC |
PE |
colour |
black and white |
black |
black and white |
black and white |
Diameter Outer [mm] |
7,3 |
7,3 |
3,6 |
6,0 |
ELECTRICAL PARAMETERS AT 20°C |
||||
Characteristic impedance [Ω] |
75 ± 3 |
75 ± 3 |
75 ± 3 |
75 ± 3 |
Capacitance [pF/m] przy f=1 kHz |
67,1 |
67,1 |
60,6 |
55,7 |
Velocity of propagation [%] |
66 |
66 |
78 |
78 |
DC resistance [mΩ/m]: |
||||
inner conductor |
38,7 |
38,7 |
176,0 |
35,6 |
outer conductor |
13,0 |
13,0 |
16,6 |
23,3 |
Attenuation [dB/100 m] – average, at frequency [MHz]: |
||||
50 |
5,8 |
5,8 |
11,8 |
6,0 |
100 |
8,4 |
8,4 |
16,9 |
8,3 |
200 |
11,7 |
11,7 |
24,4 |
11,8 |
800 |
26,5 |
26,5 |
49,6 |
25,8 |
1000 |
30,3 |
30,3 |
55,7 |
29,2 |
2400 |
50,9 |
50,9 |
46,2 |
|
Return loss [dB] - min. |
20 |
20 |
20 |
20 |
Shielding attenuation [dB] - min. |
75 |
40 |
40 |
40 |
OTHERS DATA |
||||
Reference standards |
IEC 60096-2A |
IEC 60096-2A |
IEC 60096-2A |
IEC 60096-2A |
Operating temperature range [°C] |
-20 ¸ +70 |
-40 ¸ +70 |
-20 ¸ +70 |
-20 ¸ +70 |
Minimum bending radius [mm] |
45 |
48 |
18 |
40 |
Weight [kg/km] |
64,5 |
64,5 |
17,5 |
37 |
|
|
|
|
|
Cable name |
YWDXpek (T1) 75 1,0/4,8 |
YWDXpek 75 1,0/4,8 |
XWDXpek 75 1,0/4,8 |
RG 6 L1/U |
Product No. |
0258 013 |
0258 010 |
0258 005 |
0221 021 |
CONSTRUCTION |
||||
Inner conductor: |
||||
material |
Cu |
Cu |
Cu |
Cu |
number and diameter of wires [mm] |
1x1,0 |
1x1,0 |
1x1,0 |
1x1,0 |
diameter [mm] |
1,0 |
1,0 |
1,0 |
1,0 |
Insulation: |
||||
material |
foam-skin PE |
foam-skin PE |
foam-skin PE |
foam-skin PE |
diameter [mm] |
4,8 |
4,8 |
4,8 |
4,8 |
Outer conductor: |
||||
material and CONSTRUCTION |
Al/PETP/Al tape |
Al/PETP/Al tape |
Al/PETP/Al tape |
Al/PETP/Al tape |
Sheath: |
||||
material |
PVC |
PVC |
PE |
PVC |
colour |
black and white |
black and white |
black |
black and white |
Diameter Outer [mm] |
7,3 |
7,3 |
3,6 |
6,0 |
ELECTRICAL PARAMETERS AT 20°C |
||||
Characteristic impedance [Ω] |
75 ± 3 |
75 ± 3 |
75 ± 3 |
75 ± 3 |
Capacitance [pF/m] przy f=1 kHz |
57,0 |
57,0 |
57,0 |
57,0 |
Velocity of propagation [%] |
78 |
78 |
78 |
78 |
DC resistance [mΩ/m]: |
||||
inner conductor |
22,0 |
22,0 |
22,0 |
22,0 |
outer conductor |
8,0 |
20,0 |
20,0 |
21,0 |
Attenuation [dB/100 m] – average, at frequency [MHz]: |
||||
50 |
4,6 |
6,0 |
6,0 |
6,0 |
100 |
6,4 |
8,3 |
8,3 |
8,3 |
200 |
9,1 |
11,8 |
11,8 |
11,8 |
800 |
20,2 |
25,8 |
25,8 |
25,8 |
1000 |
22,0 |
29,2 |
29,2 |
29,2 |
2400 |
38,5 |
46,2 |
46,2 |
46,2 |
Return loss [dB] - min. |
20 |
20 |
20 |
20 |
Shielding attenuation [dB] - min. |
75 |
75 |
75 |
75 |
OTHERS DATA |
||||
Reference standards |
IEC 60096-2A |
IEC 60096-2A |
IEC 60096-2A |
IEC 60096-2A |
Operating temperature range [°C] |
-20 ¸ +70 |
-20 ¸ +70 |
-40 ¸ +70 |
-20 ¸ +70 |
Minimum bending radius [mm] |
45 |
45 |
60 |
45 |
Weight [kg/km] |
57 |
43 |
37 |
45 |
|
|
|
|
|
Cable name |
11F 75 1,63/7,25 |
RG 62 |
RG 71 |
RG 63 |
Product No. |
0001 002 |
0221 003 |
0221 005 |
0221 001 |
CONSTRUCTION |
||||
Inner conductor: |
||||
material |
Cu |
Fe-Cu |
Fe-Cu |
Fe-Cu |
number and diameter of wires [mm] |
1x1,63 |
1x0,64 |
1x0,64 |
1x0,64 |
diameter [mm] |
1,0 |
0,64 |
0,64 |
0,64 |
Insulation: |
||||
material |
foam-skin PE |
PE- air |
PE- air |
PE- air |
diameter [mm] |
7,25 |
3,7 |
3,7 |
7,2 |
Outer conductor: |
||||
material and CONSTRUCTION |
Al/PETP/Al |
braid Cu |
braid Cu |
|
Sheath: |
||||
material |
PVC |
PVC |
PE |
PVC |
colour |
black and white |
black |
black |
black and white |
Diameter Outer [mm] |
10,0 |
6,15 |
6,2 |
10,4 |
ELECTRICAL PARAMETERS AT 20°C |
||||
Characteristic impedance [Ω] |
75 ± 3 |
93 ± 5 |
93 ± 5 |
125 ± 6 |
Capacitance [pF/m] przy f=1 kHz |
57,0 |
44,5 |
43,4 |
33,1 |
Velocity of propagation [%] |
78 |
83 |
83 |
84 |
DC resistance [mΩ/m]: |
||||
inner conductor |
8,0 |
138,8 |
138,8 |
138,8 |
outer conductor |
14,5 |
8,0 |
4,5 |
3,3 |
Attenuation [dB/100 m] – average, at frequency [MHz]: |
||||
50 |
3,1 |
6,3 |
6,5 |
4,3 |
100 |
4,4 |
9,2 |
9,3 |
6,2 |
200 |
6,4 |
12,6 |
13,3 |
8,8 |
800 |
14,0 |
26,1 |
28,1 |
18,1 |
1000 |
16,0 |
30,8 |
31,8 |
20,4 |
2400 |
29,4 |
|||
Return loss [dB] - min. |
20 |
20 |
20 |
20 |
Shielding attenuation [dB] - min. |
75 |
40 |
50 |
40 |
OTHERS DATA |
||||
Reference standards |
IEC 60096-2A |
MIL-C-17/30D |
MIL-C-17/90A |
MIL-C-17/30D |
Operating temperature range [°C] |
-20 ¸ +70 |
-20 ¸ +70 |
-40 ¸ +70 |
-40 ¸ +70 |
Minimum bending radius [mm] |
60 |
35 |
35 |
110 |
Weight [kg/km] |
93 |
56 |
57 |
125 |
|
|
|
|
Cable name |
RG 58 (3) C/U |
XzWDXpekw 75 1,0/4,8 |
11F (3) 75 1,63/7,25 |
Product No. |
0221 013 |
0276 002 |
0001 004 |
CONSTRUCTION |
|||
Inner conductor: |
|||
material |
CuSn |
Cu |
Cu |
number and diameter of wires [mm] |
19x0,18 |
1x1,0 |
1x1,63 |
diameter [mm] |
0,9 |
1,0 |
1,63 |
Insulation: |
|||
material |
PE |
foam-skin PE |
foam-skin PE |
diameter [mm] |
2,95 |
4,8 |
7,25 |
Outer conductor: |
|||
material and CONSTRUCTION |
braid CuSn |
Al/PETP/Al tape |
Al/PETP/Al tape |
Sheath: |
|||
material |
gel |
gel |
gel |
colour |
black |
black |
black |
Diameter Outer [mm] |
6,8 |
8,4 |
11,5 |
ELECTRICAL PARAMETERS AT 20°C |
|||
Characteristic impedance [Ω] |
50 ± 2 |
75 ± 3 |
75 ± 3 |
Capacitance [pF/m] przy f=1 kHz |
103,0 |
60,0 |
60,0 |
Velocity of propagation [%] |
66 |
78 |
78 |
DC resistance [mΩ/m]: |
|||
inner conductor |
32,5 |
22,0 |
8,0 |
outer conductor |
13,4 |
9,2 |
8,5 |
Attenuation [dB/100 m] – average, at frequency [MHz]: |
|||
50 |
11,4 |
4,6 |
3,1 |
100 |
16,6 |
6,4 |
4,4 |
200 |
24,4 |
9,1 |
6,4 |
800 |
73,0 |
20,2 |
14,4 |
1000 |
87,0 |
22,0 |
16,7 |
2400 |
38,5 |
31,0 |
|
Return loss [dB] - min. |
20 |
20 |
20 |
Shielding attenuation [dB] - min. |
75 |
75 |
75 |
OTHERS DATA |
|||
Reference standards |
MIL-C-17 |
IEC 60096-2A |
IEC 60096-2A |
Operating temperature range [°C] |
-40 ¸ +70 |
-40 ¸ +70 |
-40 ¸ +70 |
Minimum bending radius [mm] |
70 |
90 |
120 |
Weight [kg/km] |
58 |
74 |
111,0 |
SPECIAL CABLES PS-Y-29 |
Technical Data sheet |
|
Hybrid cables PS-Y-29 intended for operation in CCTV networks.
Cables are equipped with coax WD 75-0,59/3,7 for visual signal transmission and a group of insulated conductors for camera power supply and control signals transmission.
The cables are suitable for fixed indoor and outdoor installations.
CONSTRUCTION
coaxial cable WD 75-0,59/3,7
- soft solid copper conductor, diameter 0.59 mm,
- polyethylene (PE) insulation, diameter 3.7 mm,
- copper wire braid,
LiY wires
- flexible, multiwire conductors, stranded of bare annealed copper wires (tin-plated on request), meeting requirements of class 5 per PN-EN 60228,
- PVC insulation - identification colour code in accordance with DIN VDE 47100,
- insulated conductors twisted into pair,
- pair wrapped in polyester tape,
PS-Y-29 cable
- white (RAL 9010) PVC cable sheath, (8 shape) extruded on the parallel arranged coaxial and pair of insulated conductors, other colours also available.Coaxial cable WD 75-0,59/3,7
Characteristic impedance 75 ± 3 Ω
Capacitance at 1 kHz, approximate 67 nF/km
Velocity of propagation 66 %
DC resistance at 20°C, approximate
inner conductor 63 Ω/km
outer conductor 27.2 Ω/km
LiY wires
Operating voltage Uo/U 300/300 V
Operating voltage, peak value 500 V
Voltage test 1500 V rms
DC conductor resistance at 20°C, maximum:
conductor 0.50 mm2 39.0 Ω/km
conductor 0.75 mm2 26.0 Ω/km
conductor 1.0 mm2 19.5 Ω/km
Insulation resistance, minimum 20 MΩ∙km
Inductance, approximate 0.7 mH/km
Cable PS-Y-29
Operating temperature range
during operation from - 30 to + 70°C
during installation from - 10 to + 50°C
Minimum bending radius 10 x cable diameter
Cable combustibility flame retardant
Combustibility tests PN-EN 60332-1-2, IEC 60332-1-2
Reference standards
coaxial cable PN-91/T-90601, IEC 61156-1
LiY wires DIN VDE 0812
The cable meets requirements of the low voltage directive 2014/35/EU
Attenuation loss [dB/100m] average - at frequency [MHz]: |
|
1 |
1.0 |
50 |
7.4 |
100 |
10.5 |
200 |
15.1 |
300 |
18.8 |
500 |
24.8 |
800 |
32.0 |
1000 |
36.3 |
1500 |
45.6 |
2000 |
55.7 |
2400 |
56.9 |