LOCAL AREA NETWORK CABLES Technical Data sheet
 

 

 acrobat reader_50x50  

APPLICATIONS

UTP (L) kat.5e 4x2x0,5 mm cables are intended for multimedia computer networks (data, sound and HDTV transmission), including structural wiring of buildings, applied in industrial and other dedicated networks not sensitive to electromagnetic interferences.

The cables are also applied in computer networks of increased binary transfer where simultaneous transmission in both directions in all 4 symmetrical circuits is used (full duplex, Gigabit Ethernet technique).

The cables are suitable for fixed indoor installations.

CONSTRUCTION

- annealed copper single wire conductors of diameter 0.48 mm, 24 AWG,

- polyethylene (PE) insulation coloured: white-blue and blue, white-orange and orange, white-green and green, white-brown and brown,

- insulated conductors twisted into pairs,          

- pairs laid-up into a cable core,

- PVC cable sheath, grey RAL 7035, other colours also available.

AVAILABLE UPON REQUEST

UTP-H (L) kat.5e 4x2x0,5 mm - halogen free material sheathed cables applied in locations where, in case of fire, higher safety level is required. The cables are flame retardant and their smoke emission is low, emitted fumes are non toxic and non corrosive.

CHARACTERISTICS

Characteristic impedance          100 ± 15 Ω

Mutual capacitance of any pair at 1 kHz, approximate              50 nF/km

Capacitance unbalance of anypair to ground at 1 kHz,  max.      1600 pF/km

Insulation resistance, minimum          5000 MΩ∙km

Operating voltage    150 V

Voltage test    700 V rms

Velocity of propagation           65 %

Return loss, minimum at f=4¸10 MHz         20+5lg(f) dB

Return loss, minimum at f=10¸20 MHz       25 dB

Return loss, minimum at f=20¸155 MHz     25-7lg(f/20) dB

DC loop resistance at 20°C, maximum        210 Ω/km

Resistance unbalance of any pair of conductors, max.         2 %

Phase delay dispersionof symmetrical circuits                     45 ns/100 m

Phase delay T                                 534+36/Öf ns/100 m

Operating temperature range

      during operation                        from - 20 to + 70°C
      during installation                      from     0 to + 50°C

Minimum bending radius                 4 x cable diameter

Cable combustibility                        flame retardant

Combustibility tests                         PN-EN 60332-1-2, IEC 60332-1-2

Reference standards                       PN-EN 50288-3-1, IEC 61156-5, ISO/IEC 11801, TIA/EIA 568 A

Attenuation loss, maximum

f

[MHz]

1

4

8

10

16

20

25

31.25

62.5

100

155

A

[dB/100 m]

2.1

4.3

5.9

6.6

8.2

9.2

10.5

11.8

17.1

22.0

28.1

 

Near end cross-talk between pairs, minimum

f

[MHz]

1

4

8

10

16

20

25

31.25

62.5

100

155

NEXT

[dB]

65.3

56.3

51.8

50.3

47.3

45.8

44.3

42.9

38.4

35.3

32.5

PSNEXT

[dB]

62.3

53.3

48.8

47.3

44.3

42.8

41.3

39.9

35.4

32.3

29.5

ACR

[dB]

68.3

57.2

51.0

48.8

44.0

41.5

38.9

36.2

26.4

18.3

4.4

 

Far end cross-talk between pairs, minimum

f

[MHz]

1

4

8

10

16

20

25

31.25

62.5

100

155

ELFEXT

[dB]

63.8

51.7

45.7

43.8

39.7

37.7

35.8

33.9

27.8

23.8

19.9

PSELFEXT

[dB]

60.8

48.7

42.7

40.8

36.7

34.7

32.8

30.9

24.8

20.8

16.9

 

The cable meets requirements of the low voltage directive 2014/35/EU