TELECOMMUNICATION SWITCHBOARD CABLES | Technical Data sheet |
|
|
APPLICATIONS
YTKSYekw are multipair cables intended for interconnections between switching and transmission equipment, for analogue or digital data transmission in industrial electronics and control applications.
The cables are protected by an overall electrostatic shield against external electric interferences.
The cables are suitable for fixed indoor installations.
CONSTRUCTION
- bare annealed copper single wire round conductors of diameter 0.5; 0.6; 0.8 i 1.0 mm,
- PVC insulation - identification colour code according to PN-92/T-90321,
- insulated conductors twisted into pairs,
- pairs laid-up in layers,
- overall electrostatic shield incorporating aluminium-polyester tape and annealed tinned copper single drain wire,
- PVC cable sheath, white RAL 9010, other colours also available.
AVAILABLE UPON REQUEST
HTKSHekw - halogen free cables, applied when higher safety in case of fire is required. The cables are flame retardant, their smoke emission in fire is low and released gases are not corrosive.
CHARACTERISTICS
Conductor diameter |
mm |
0.5 |
0.6 |
0.8 |
1.0 |
DC conductor resistance at 20°C, maximum |
Ω/km |
195.6 |
135.8 |
75.0 |
48.0 |
Voltage test - AC voltage for 60s - DC voltage |
V rms V |
1000 1500 |
1000 1500 |
1500 2250 |
1500 2250 |
Mutual capacitance of pair at 1 kHz - maximum - average |
nF/km |
120 110 |
120 110 |
120 100 |
120 100 |
Operating voltage Insulation resistance, minimum Inductance, approximate |
150 V 200 MΩ·km 0.7 mH/km |
Operating temperature range during operation during installation Minimum bending radius Cable combustibility Combustibility tests Reference standards |
from - 30 to + 80°C from - 5 to + 50°C 10 x cable diameter flame retardant PN-EN 60332-1-2, IEC 60332-1-2 PN-92/T-90321, PN-92/T-90320 |
The cable meets requirements of the low voltage directive 2014/35/EU
Other cross-sections and pair counts available on request.
TECHNOKABEL S.A. reserves the right to change specifications without prior notice.